—— PRODUCT · FAR.M OPERATIONS

Reveal chemical insights

FAR.M pipelines are a series of operations that remove noise and drift in raw GC-MS and LC-MS data to reveal key chemical differences between samples. They are hosted in a web-based D2i.Ops Centre

Ready-made pipelines combine the FAR.M operations, from a single step to the full Chrom.BaseCorrect → Chrom.ApexAlign → Chrom.Delta run.

FFilterChrom.BaseCorrectRemoves baseline noise and column bleed, isolating the true signal without altering spectral integrity.
AAlignChrom.ApexAlignCorrects retention-time drift across instruments, columns, sites and years.
RRevealChrom.DeltaAn adjustable Chrom.Delta Threshold (CDT) reveals chemicals present in one sample but not the other.
MMergeHarmoniseCombines verified results with sample metadata, libraries and other sources.
+Your operationthird-party · tailoredSlots into the same chain.

Each operation hands verified data to the next; the chain is saved, versioned and tracked at every step. Add your existing or third-party operations to the same pipeline; where nothing suitable exists, we engineer tailored operations.

R · REVEAL · CHROM.DELTA

Spot true differences

Simply subtracting one chromatogram signal from another leaves hundreds of residual peaks that differ only in intensity. Chrom.Delta uses a multistage rejection algorithm to filter out such intensity differences to reveal those chemicals present in one but not the other sample.

Case study · WP01

A fruit juice from a new supplier was compared with an approved reference. At CDT 900 one peak remained: a known packaging migrant, traced to a PVC cap liner.

WP01 includes three case studies: Rocket salad ageing, packaging migration in juice and polymer ageing.

Reference
Chromatogram of the approved reference juice
Test
Chromatogram of the test juice
Test – reference
Chrom.Delta result at CDT 900 showing one remaining peak
Chrom.Delta at CDT 900: one unique peak remains in the test sample.
Pre-aligned
Two GC-MS runs with retention-time drift before alignment
Post-aligned
The same runs overlaid after Chrom.ApexAlign
Both runs baseline-subtracted with Chrom.BaseCorrect; Chrom.ApexAlign then removes the retention-time drift between them.

A · ALIGN · CHROM.APEXALIGN

Compare runs years apart

Retention-time drift makes runs from different instruments, columns or years hard to compare. Chrom.ApexAlign aligns GC-MS and LC-MS data automatically, so legacy data can be compared directly.

WHERE IT IS USED

One pipeline, many applications

Target analysis
  • Batch acceptance
Target / non-target screening
  • Extractables & leachables
  • Shelf life & stability
  • Quality investigations
  • Substances of concern
Non-target analysis
  • Competitive intelligence
  • Product profiling
  • Biomarker discovery

See FAR.M run on your data

Or read the handout: Reveals chemical insights and Harmonises data workflows.